NanoPhotometer® P-Class

Product Specifications


NANOVOLUME FEATURE

Detection range dsDNA: from 2 ng/µl to 18,750 ng/µl, BSA: from 0.08 mg/ml to 543 mg/ml
Absorbance range 0.01 – 1.5 (10 mm equivalent: 0.05 – 375)
Minimum sample size 0.3 μl
Path lengths 0.04 mm, 0.1 mm, 0.2 mm, 1 mm and 2 mm
Virtual dilution factors 5, 10, 50, 100 and 250

SPECTROMODULE

Wavelength range 190 – 1,100 nm
Wavelength scan range 200 – 950 nm
System start up time Less than 5 seconds, no warm up necessary
Measure time for full scan range     3.5 seconds
Wavelength reproducibility < ± 0.2 nm
Wavelength accuracy ± 2nm
Bandwidth Better than 5nm
Stray light < 0.5% at 220 nm using NaI and 340 nm using NaNO2
Photometric range -0.3 – 2.499 A 0-199% T
Detection Range dsDNA: 0.5 ng / µl to 125 ng / µl, BSA: 0.02 mg / ml to 3.6 mg / ml
Absorbance reproducibility ±0.003 A (0 to 0.5 A), ±0.007 A (0.5-1.0 A) @ 260 nm
Absorbance accuracy ±0.005 A or ±1% of the reading, whichever is the greater
Zero stability ±0.003 A/hour after 20 min warm up @ 340 nm
Noise 0.002 A rms at 0 A @ 260 nm
0.005 A (pk to pk) at 0 A @ 260 nm
Optical arrangement Dual channel Czerny Turner with flat grating,1024 pixel CCD array, concave mirrors
Lamp Xenon flash lamp
Lifetime 109 flashes, up to 10 years
Cell types 15 mm centre height (z-height), outside dimension 12.5 mm x 12.5 mm

OTHER TECHNICAL DATA

Vortexer 2,800 rpm; tube size up to 2.0 ml
Cuvette storage capacity for eight 10 mm cells
Photometric mode Abs, %T, concentration, scan, ratio, multi wavelength, kinetics in Abs x factor / min
Method storage Up to 81 methods in user methods
Built-in methods Nucleid acid, microarray (labeling efficiency), protein and cell density
Display formats 320 x 240 pixels
Size 140 mm x 275 mm x 380 mm
Weight < 4.5 kg
Operating voltage 90-250 V, 50/60 Hz, Max 30 VA
Input / Output ports SD Memory Card, USB or Bluetooth for connection to a PC for direct data download, printout and data storage
Performance verification Auto diagnostics when switched on
Features and specifications are subject to change without notice
  • "The outstanding features of the NanoPhotometer® are the clearly arranged software and the easy handling..."

  • "Using very little amount of DNA/RNA samples and the high accuracy are major advantages of this device!"

  • "We bought our first NanoPhotometer® from Implen 18 months ago and have been very happy with it ever since."

  • "The Nanophotometer® is so easy to use, it is fast and reliable. The flexibility is great..."

  • "The NanoPhotometer from Implen is a real workhorse in our lab. The Implen Support team is very responsive and of great help!"